Kit Anestesia Epidural Pakai Buang - Aplikasi Klinikal

Oct 15, 2026 Viewd 8

Disposable Epidural Anesthesia Puncture Kit

Clinical Application & Core Usage Advantages

News · October 15, 2026 · Sujia Medical

A sterile, all-in-one solution for regional anesthesia and pain management.

epidural-kit-1

What is a disposable epidural puncture kit?

The kit is a pre-sterilized tray that gathers the routine sterile supplies for an epidural procedure in one package. Normally, staff must collect several separate items before every case.

By cutting that assembly step, the kit can help standardize epidural preparation and may improve efficiency, safety and infection control when used under institutional protocols.

Core values at a glance

Efficiency – Preparation time was cut by roughly 30% in internal workflow evaluations; actual results may vary.

Safety – Includes sterile barrier components, with EO sterilization as labeled.

Reliability – Supports a steady, standardized clinical workflow.

Compatibility – Standard Luer-lock connector for compatible devices.

Core clinical application scenarios

epidural-kit-2epidural-kit-3

ObstetricsLabor analgesia and C-section, where epidural anesthesia is indicated.

Operating RoomSurgical anesthesia and support.

Pain ClinicChronic pain management, where epidural techniques are indicated.

Post-op PCAPatient-controlled analgesia (PCA/PCEA), where applicable.

ADVANTAGE 01

Ready to use out of the box, with no extra sorting

Everything routinely needed for the procedure comes pre-assembled in one sterile tray. Staff check that the packaging is intact and open it, instead of counting and matching needles, syringes, drapes and accessories each time.

~30%*

Shorter pre-procedure preparation in internal workflow evaluations, a good fit for emergency and obstetric settings. Actual results may vary.

*Internal workflow evaluation data. Not a clinical endpoint. Actual results may vary.

ADVANTAGE 02

Precision puncture design supports accurate depth control

epidural-kit-4

The puncture needle is medical-grade stainless steel with a Tuohy-type blunt-bevel tip and clear depth markings along the shaft.

Tactile feedback helps anesthesiologists sense entry into the epidural space, and the visible scale supports precise depth control. In trained hands, this may help lower the risk of unintended dural puncture.

ADVANTAGE 03

Atraumatic catheter design and Luer-lock compatibility

Atraumatic tip

The matched catheter has a rounded tip and smooth side holes, balancing flexibility and support. It slides through the needle with low resistance and is designed to limit irritation of nerve roots and vessels.

Standard Luer lock

A standard Luer-lock connector fits matching syringes, analgesic pumps and infusion devices, with no extra adapter. The connection is designed to be tight and leak-resistant.

Clear depth markings

Visible marks on the catheter let clinicians confirm indwelling depth during placement, which may mean fewer adjustments and better placement accuracy.

ADVANTAGE 04

Built-in sterile barrier for reliable infection control

A sterile fenestrated drape, sterile gloves and disinfection supplies help set up a sterile field when used with standard aseptic technique. EO-compatible parts are EO sterilized, and the rest follow their labeling. The kit has a two-year sterile shelf life when stored as labeled.

Sterile barrier components

One package helps complete the sterile barrier setup.

EO sterilization as labeled

Packaging carries clear process indicators. They confirm process exposure but do not replace sterility assurance.

Single-use design

Used once and discarded properly, the kit helps reduce cross-infection risk between patients.

Targeted value for clinical departments

Obstetrics

For time-sensitive labor analgesia, a ready-to-use tray can shorten setup, and the atraumatic catheter is intended to reduce placement irritation. Postpartum back pain has many causes and should not be blamed on epidural puncture alone.

Operating Room

A standardized configuration unifies anesthesiologists' workflow, reduces variation from personal habits and makes preparation more consistent. Nurses also spend less time sorting consumables.

Pain Clinic

For repeated epidural drug administration where indicated, a single-use kit lowers cross-infection risk between patients. Light, individually packed kits are easy to carry for outpatient work.

Ready to learn more?